Kirchhoff’s Laws
KCL: ΣIk = 0 at every node (charge conservation). KVL: ΣVk = 0 around every loop (energy conservation; the electric field is conservative in the lumped-circuit approximation). Together with component laws (V = IR, etc.) they give a linear system for the unknown currents, solved by node or mesh analysis. KVL fails when changing magnetic flux links the loop, which is accounted for by treating inductors as circuit elements.
Curious
Gustav Kirchhoff formulated these rules in 1845 as a student. They are used in every circuit simulator today.
Exploring
Deep Dive
Validity. The laws are the lumped-element approximation of Maxwell’s equations, valid when the circuit is small compared with the wavelength of the signals. At high frequency, transmission-line theory is needed. Network theorems (Thévenin, Norton, superposition) follow from linearity.
Related. See Electrical Resistance, AC Circuits and Faraday’s Law.
Concept Relationship Map
Requires: Ohm’s law, electric potential
Enables: circuit analysis, AC circuits
Commonly confused with: Kirchhoff’s laws of spectroscopy and radiation
Sources
- Purcell, E.M., Morin, D.J. (2013). Electricity and Magnetism (3rd ed.). Cambridge University Press.
- Horowitz, P., Hill, W. (2015). The Art of Electronics (3rd ed.). Cambridge University Press.
- Kirchhoff, G. (1845). Annalen der Physik, 140, 497–514.