Reading time: 9 minConfidence: HighLast verified: October 2026

In Raman scattering, an incident photon of frequency ν0 scatters from a molecule and emerges at ν0 − νm (Stokes) after leaving the molecule with one vibrational quantum hνm, or at ν0 + νm (anti-Stokes) after taking one from a molecule already excited. The Raman shift, quoted in wavenumbers, is Δν̃ = 1/λ0 − 1/λs (cm−1) and is independent of the excitation wavelength. A vibration is Raman-active if it changes the molecular polarisability. The anti-Stokes to Stokes intensity ratio is [(ν0 + νm)/(ν0 − νm)]4 e−hνm/kBT.

Curious

One sentence that captures itWhen light bounces off a molecule, a tiny fraction comes back a slightly different colour, because it traded a little energy with the molecule’s vibrations.

Almost all scattered light keeps its colour, which is why the sky is blue (Rayleigh scattering). But about one photon in a million or more comes back slightly redder or bluer. The change in colour matches the vibration frequencies of the molecule, so measuring it gives a fingerprint of the substance.

The effect was found in India in 1928 by C. V. Raman and K. S. Krishnan, using filtered sunlight and a simple setup. Raman received the 1930 Nobel Prize in Physics, the first Asian scientist to win a Nobel in the sciences. India celebrates National Science Day on 28 February to mark the discovery. Raman spectroscopy is now used in pharmaceuticals, art conservation, geology, forensic work and planetary exploration.

Exploring

Worked examples(1) With green 532 nm laser light, diamond’s 1,332 cm−1 line appears at 572.6 nm (Stokes), silicon’s 520 cm−1 line at 547.1 nm, and the N2 stretch (2,331 cm−1) at 607.3 nm. (2) A shift of 1 cm−1 corresponds to a frequency of about 30 GHz. (3) At 300 K the anti-Stokes to Stokes intensity ratio is about 0.10 for silicon (520 cm−1) and about 0.003 for diamond (1,332 cm−1), because few molecules are vibrationally excited; this ratio is also used as a thermometer. (Computed in Python.)
ScatteringEnergy changeRelative strength
RayleighNone (elastic)Strongest scattered component
Stokes RamanPhoton loses hνmRoughly 10−6–10−8 of the Rayleigh intensity
Anti-Stokes RamanPhoton gains hνmWeaker than Stokes by the Boltzmann factor
Resonance / surface-enhancedExcitation near an electronic transition or a metal nanostructureCan be enhanced by orders of magnitude
Common mistake — Commonly ConfusedRaman scattering is not fluorescence. Fluorescence involves absorption into a real excited electronic state followed by re-emission after a delay (nanoseconds); Raman scattering is a virtual, essentially instantaneous process, and its shift stays the same when the laser colour changes, whereas fluorescence peaks stay at fixed wavelengths. Also, Raman and infrared spectroscopy are complementary: a vibration is infrared-active if the dipole moment changes and Raman-active if the polarisability changes.

Deep Dive

Primary sourceRaman, C.V., Krishnan, K.S. (1928). “A new type of secondary radiation.” Nature, 121, 501–502; Smekal, A. (1923). “Zur Quantentheorie der Dispersion.” Die Naturwissenschaften, 11, 873–875.

Discovery. Adolf Smekal predicted inelastic scattering of this kind in 1923. Raman and Krishnan observed it in liquids in Calcutta in February 1928 and reported it in Nature that March. Grigory Landsberg and Leonid Mandelstam independently observed the effect in quartz in Moscow, reporting it later in 1928; the credit for the discovery, and the fact that the Nobel Prize went to Raman alone, has been discussed by historians. Laser sources from the 1960s and sensitive detectors made Raman spectroscopy routine.

Theory. The oscillating electric field induces a dipole p = αE. If the polarisability depends on the nuclear coordinate q, α = α0 + (∂α/∂q)q0 cos(2πνmt), then the induced dipole contains components at ν0, ν0 − νm and ν0 + νm. The classical picture gives the frequencies but not the Stokes/anti-Stokes asymmetry, which needs quantum theory: the Stokes process starts from the ground vibrational state, which is occupied by most molecules, while anti-Stokes requires an excited state with Boltzmann population e−hνm/kT (see Partition Function). The factor ((ν0 + νm)/(ν0 − νm))4 comes from the ν4 dependence of scattering. Vibrational energies come from the harmonic-oscillator spectrum (see Quantum Harmonic Oscillator).

Variants and uses. Stimulated Raman scattering, in which an intense beam amplifies the Stokes wave, underlies Raman lasers and amplifiers (see Non-Linear Optics). Surface-enhanced Raman spectroscopy (SERS), discovered in the 1970s, can detect single molecules under some conditions. Coherent anti-Stokes Raman scattering (CARS) is used for label-free imaging. Raman instruments have flown on Mars rovers, with SuperCam on Perseverance (2021) combining Raman and other spectrometers. Raman spectroscopy identifies diamond, graphene layers (the G and 2D bands) and mineral phases without destroying the sample.

Sources

  • Raman, C.V., Krishnan, K.S. (1928). Nature, 121, 501–502.
  • Smekal, A. (1923). Die Naturwissenschaften, 11, 873–875.
  • Long, D.A. (2002). The Raman Effect. Wiley.
  • The Nobel Prize in Physics 1930, NobelPrize.org.
  • Demtröder, W. (2014). Laser Spectroscopy (4th ed.). Springer.
Last verified: October 2026 · Source: Raman & Krishnan (1928); Smekal (1923); Long (2002) · Confidence: high