Spectroscopy · Concept

Spectroscopy

Reading time: 9 minConfidence: HighLast verified: October 2026

Spectroscopy analyses the interaction of radiation with matter as a function of wavelength. Atoms and molecules have discrete energy levels, so transitions between them occur at frequencies ν = (Eu − El)/h, giving spectral lines that act as fingerprints. Line positions identify species, intensities give abundance and temperature, widths give temperature, pressure and lifetime (Doppler width ΔνD = ν0√(8kBT ln 2/mc2); natural width Δν = 1/2πτ), and shifts give motion by the Doppler effect. The absorption of light in a sample follows the Beer–Lambert law, A = εcl.

Curious

One sentence that captures itEvery chemical element and molecule gives off or soaks up its own pattern of colours, like a barcode, and spectroscopy reads the barcode.

Pass sunlight through a prism and you get a rainbow crossed by hundreds of thin dark lines. Each line is a colour absorbed by a particular element in the Sun’s atmosphere or in the Earth’s. Heat salt in a flame and it glows a particular yellow: a bright line from sodium. By reading these patterns, scientists learn what a star is made of without going there.

Spectroscopy is used in astronomy, chemistry, medicine (such as pulse oximetry), forensics, environmental monitoring and quality control. It also shaped quantum physics itself: the puzzling line patterns of atoms, especially hydrogen (see Hydrogen Spectrum), led to Bohr’s model and then to quantum mechanics.

Exploring

Worked examples(1) The sodium D lines at 588.995 and 589.592 nm differ by 0.597 nm, so resolving them needs a resolving power R = λ/Δλ ≈ 589/0.597 ≈ 990 or better. (2) Doppler width of the Balmer-alpha line (656.3 nm) for hydrogen at 5,000 K: ΔνD ≈ 23 GHz, or 0.033 nm. (3) Doppler width for sodium at 589 nm and 500 K: about 1.7 GHz, while the natural width of the sodium D lines (excited-state lifetime about 16.3 ns) is about 9.8 MHz, so in a vapour Doppler broadening dominates by a factor of about 170. (4) An absorbance A = 1 means 10% of the light is transmitted; A = 2 means 1%. (Computed in Python.)
MethodWhat is measuredTypical use
EmissionLight given off by excited atoms or moleculesFlame tests, stars, plasma analysis
AbsorptionLight removed from a continuous sourceChemistry (UV-vis, infrared), stellar atmospheres
Scattering (Raman)Inelastically scattered lightMolecular fingerprinting without sample preparation
FluorescenceLight re-emitted at longer wavelengthBiology, imaging, forensics
Laser / high-resolutionNarrow lines, Doppler-free techniquesAtomic clocks, precision tests
Common mistake — Commonly ConfusedSpectroscopy does not require visible light: radio, microwave, infrared, ultraviolet, X-ray and gamma-ray spectroscopy are all in common use, and techniques such as NMR and mass spectrometry share the name “spectroscopy” or “spectrometry” though mass spectrometry separates ions by mass and not by wavelength.

Deep Dive

Primary sourceKirchhoff, G., Bunsen, R. (1860). “Chemische Analyse durch Spectralbeobachtungen.” Annalen der Physik und Chemie, 110, 161–189; Beer, A. (1852). “Bestimmung der Absorption des rothen Lichts in farbigen Flüssigkeiten.” Annalen der Physik und Chemie, 86, 78–88.

History. Isaac Newton dispersed sunlight with a prism in the 1660s and coined the word “spectrum”. William Hyde Wollaston saw dark lines in 1802, and Joseph von Fraunhofer mapped hundreds of them from 1814, labelling the strongest with letters still in use (such as the D lines of sodium). In 1859–1860 Gustav Kirchhoff and Robert Bunsen showed that each element has a characteristic spectrum and that the dark solar lines match bright emission lines of elements on Earth (see Emission Spectra and Absorption Spectra). The method led Bunsen and Kirchhoff to discover caesium (1860) and rubidium (1861). Helium was identified in the Sun’s spectrum in 1868, before it was found on Earth in 1895. Johann Balmer’s formula for hydrogen lines (1885) preceded quantum theory.

Instruments. A spectrometer needs a dispersing element, such as a prism or diffraction grating, or an interferometer in the case of Fourier-transform instruments (see Interference), plus a detector. Resolving power R = λ/Δλ for a grating is mN (order times illuminated lines). Fourier-transform infrared spectrometers measure an interferogram from a moving mirror and compute the spectrum numerically, gaining light throughput.

Line shapes. Natural broadening arises from finite lifetime τ through the uncertainty principle (see Uncertainty Principle) and gives a Lorentzian profile of width 1/2πτ. Doppler broadening, from the thermal speed distribution (see Maxwell–Boltzmann Distribution), gives a Gaussian profile. Collisional (pressure) broadening gives a Lorentzian. The combination of Gaussian and Lorentzian is the Voigt profile. Laser techniques such as saturated absorption and two-photon spectroscopy remove the Doppler width, which made precision measurements of hydrogen and optical frequency standards possible (see Non-Linear Optics). The Beer–Lambert law holds for dilute solutions and fails at high concentrations or when scattering or fluorescence is present.

Sources

  • Kirchhoff, G., Bunsen, R. (1860). Annalen der Physik und Chemie, 110, 161–189.
  • Beer, A. (1852). Annalen der Physik und Chemie, 86, 78–88.
  • Demtröder, W. (2014). Laser Spectroscopy (4th ed.). Springer.
  • Herzberg, G. (1944). Atomic Spectra and Atomic Structure. New York: Dover.
  • Hecht, E. (2017). Optics (5th ed.). Pearson.
Last verified: October 2026 · Source: Kirchhoff & Bunsen (1860); Beer (1852); Demtröder (2014) · Confidence: high